+38 (048) 740 70 47 For calls from the UA Submit request

en ua ru Pl

Українська версія сайту

Ви завжди зможете переключити мову сайту, скориставшись перемикачем.

Scientific-industrial corporation

AGRO-SIMO-MASHBUD

company with limited responsibility

Menu

Medium pressure radial fan ВСД

Medium pressure radial fan ВСД is designed to be installed in the grain and its products pneumatic transport systems, in the aspiration systems of the equipment and machines as an exhauster for transporting air and other gas mixes, free from adhesives, fibres, with dust and other solids content up to 100 mg/m3.

Purpose:

Medium pressure radial fan ВСД is designed to be installed in the grain and its products pneumatic transport systems, in the aspiration systems of the equipment and machines as an exhauster for transporting air and other gas mixes, free from adhesives, fibres, with dust and other solids content up to 100 mg/m3.

Specifications:

Parameter ВСД-6,3 ВСД-6,3 П ВСД-6,3 - ВЦ1446
1. Capacity, m3/h:
     - rated mode 6 590 7 500 6 590
     - working area 5 500 - 7 600 6 800 - 9 000 5 500 - 7 600
2. Pressure, kPa
     - rated mode 1 540 1 800 9 000
     - working area 1 500 - 1 650 1 750 - 1 850 6 000 - 12 000
3. Maximum efficiency: 0,71 0,71 0,73
4. Rotation speed of impeller, RPM: 1 440 1 800 700
5. Installed power, kW: 5,5 7,5 / 11,0 4,0
6. Diameter of impeller, mm: 630 630 630
7. Diameter of suction hole, mm: 350 350 630
8. Dimensions, mm:
     - length 986 986 1 013
     - width 767 930 1 139
     - height 1 005 1 005 1 110
9. Weight, kg: 170 215 / 255* 183,2 (including electric
engine 52,2 kg)

*Fan feed is carried out by three-phase power (neutral wire) of AC current with voltage of 380 B and frequency of 50 Hz.

The specified aerodynamic characteristics are provided under normal atmospheric conditions (density 1.2 kg/m3, barometric pressure 101.34 kPa, temperature + 20 °C and relative humidity 50%). If the fans work at increased temperature or in highlands conditions, a significant decrease in pressure is possible.

Design and principle of operation:

The fans, depending on the version, consist of:

    • The pedestal, spiral casing, work wheel (impeller), inlet nozzle, electric motor;
    • The pedestal, spiral casing, work wheel (impeller), inlet nozzle, electric motor and belt drive.

The pedestal consists of spiral casing and frame lower engine. Work wheel is mounted on the engine roller directly or through belt drive. The principle of operation of the fan is that the movement of air in it is achieved by transferring the energy of rotation of the impeller to it. If the impeller rotates clockwise when viewed from the motor side, this is a right-hand fan. If it is counterclockwise, it is left-hand fan.

We also recommend:

Fans ВР

Fans BP (radial fans) are designed in the system of air conditioning, ventilation, air heating etc. Go to

Fans ВРП (Dust radial fans)

Dust radial fan ВРП is applied in the system of the dust collecting units of grain pneumatic transportation to remove wood chips and metal dust from machines. Go to

High pressure radial fans ВВД

High pressure radial fans ВВД-5, ВВД-6.3, ВВД-7, ВВД-7Д are designed for transporting aspirated waste and ground materials in the pneumatic transport systems of flour mill equipment, and also in the cereals production lines. Go to

Low pressure fans

Fans are designed to move air flow in ventilation systems. Go to

Can't make your choice?
The manager will help you:

Up